Check what affects ball detection
Still balls not detected where they hit the wall, even after a calibration? The wall still reacts by itself? A few checks help you find what is getting in the way.
Make sure you completed all the steps in How to calibrate the camera. This article covers the checks that come after.
Follow the steps for your model in order and note the result of each step.
Choose your model:
- Unö & Duö V2 (lift)
- Möve
- Höp
- Unö & Duö V1 (lift)
- Möbil
Not sure which model you have? Identify my model
Steps for Unö & Duö V2
What you need:
- A clean microfiber cloth
- Install the updates for the Lü app, Windows, and the drivers and BIOS, as shown in Updates for Lü App, Windows, drivers and BIOS. Updates often fix detection problems.
Balls detected where they hit? You're done.
Still not detected correctly? Go to step 2.
Step 2: Check the light in the room
- Turn off the room lights while you play.
- Cover the windows, with blinds or curtains, so that no daylight reaches the wall.
- Look for a bright light aimed at the wall, such as a spotlight. Turn it off or point it elsewhere.
Balls detected where they hit? You're done.
Still not detected correctly? Go to step 3.
Step 3: Remove what moves near the wall
- Look for anything that moves near the wall: flags, banners, curtains, plants, or an air vent blowing on them.
- Remove these objects or stop them from moving.
- Make sure no one stands between the camera and the wall while you test.
Balls detected where they hit? You're done.
Still not detected correctly? Go to step 4.
Step 4: Check the wall and the floor
- Remove anything in the projection area: posters, signs, wall art.
- Look for shiny or dark areas in the projection area. The wall must be pale and matte for the camera to see the balls. If you find such an area, note where it is.
- Make sure the projection stays on the wall and does not spill onto the Heart or beyond the wall.
- Use Lü mats or no mats, and tape the seams between the mats. Remove red objects from the play area.
- If the floor in front of the wall is shiny, cover it with cardboard and test again. A shiny floor can cause interference.
Balls detected where they hit? You're done.
Still not detected correctly? Go to step 5.
Step 5: Clean the camera lens (lift required)
- Gently wipe the transparent window at the front of the camera with a clean microfiber cloth, as shown in Cleaning the camera.
- Check that the camera is still firmly attached. If it looks loose or moved, do not adjust it: tell us when you contact us.
Balls detected where they hit? You're done.
Still not detected correctly? Go to step 6.
Step 6: Calibrate the camera again
- Follow the steps in How to calibrate the camera.
- In Test mode, throw balls at different places, including the area where detection was wrong.
- If the balls are detected in test mode but not in the games, open Settings > System status and select Restart the camera.
Balls detected where they hit? You're done.
Still not detected correctly? Go to step 7.
Contact us with your results and tell us which part of the wall is affected: top, bottom, left, right or a corner.
Steps for Möve
Step 1: Do the first checks
Do steps 1 to 4 of the steps for Unö & Duö V2: updates, light, objects near the wall, wall and floor.
Step 2: Calibrate the camera again
Follow the Möve steps in How to calibrate the camera.
Step 3: Send us your results
On Möve, the camera is in the head. Cleaning or checking it requires opening the head, which must be done by trained personnel only. Do not open the head yourself.
Contact us with your results and tell us which part of the wall is affected: top, bottom, left, right or a corner.
Steps for Höp
Höp is the newest solution in the Lü ecosystem, and its help content is on the way. In the meantime, contact us: we will guide you step by step.
Steps for Unö & Duö V1
Follow the steps for Unö & Duö V2. You need a lift for step 5.
Steps for Möbil
Step 1: Do the first checks
Do steps 1 to 4 of the steps for Unö & Duö V2: updates, light, objects near the wall, wall and floor.
Step 2: Calibrate the camera again
Follow the Möbil steps in How to calibrate the camera. If you moved the Möbil, start with the camera view.
Step 3: Send us your results
On Möbil, the camera is in the main module (the head on the lifting tower). Cleaning or checking it requires opening the module, which must be done by trained personnel only. Do not open it yourself.
Contact us with your results and tell us which part of the wall is affected: top, bottom, left, right or a corner.
If the problem persists, contact us
Fill out the contact form and include:
- Your Lü serial number (LU####) (how to find it)
- Your model
- The steps you tried and the result of each
- The part of the wall where detection is wrong
- A photo or video of the problem